On-line monitoring system of faulty insulator based on non-touching UV pulse method
He,Wei1; Chen,Tao1; Liu,Xiao Ming1; Yang,Fan1; Yao,De Gui2; Xiong,Dong1
2006-05-25
Source PublicationDianli Xitong Zidonghua/Automation of Electric Power Systems
ISSN10001026
Volume30Issue:10Pages:69-74
AbstractGeneral methods of detecting faulty insulators include the distribution voltage method, the corona pulse current method, the infrared thermal imaging temperature measurement method and the ultrasonic method, etc. They have, however, certain disadvantages. A brand-new ultra-violet (UV) pulse method proposed, through highly sensitive solar-blind UV detector, can continuously monitor the special wave band of UV pulses of discharge on the surface of insulators online. The UV pulse method to detect the faulty insulator is used because the faulty insulator will increase the number of the insulator string's discharge pulses. An on-line monitoring system adopting the UV pulse method doesn't need to have a touch with the insulator, and hence is very suitable for detecting faulty insulators online with the check distance beyond 4 m. The proposed method has been verified by experiments with a 110 kV line insulator.
KeywordFaulty insulator On-line monitoring UV pulse method
URLView the original
Language英語English
Fulltext Access
Document TypeJournal article
CollectionPersonal research not belonging to the institution
Affiliation1.Chongqing University,,China
2.Henan Electric Power Research Institute,,China
Recommended Citation
GB/T 7714
He,Wei,Chen,Tao,Liu,Xiao Ming,et al. On-line monitoring system of faulty insulator based on non-touching UV pulse method[J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems,2006,30(10):69-74.
APA He,Wei,Chen,Tao,Liu,Xiao Ming,Yang,Fan,Yao,De Gui,&Xiong,Dong.(2006).On-line monitoring system of faulty insulator based on non-touching UV pulse method.Dianli Xitong Zidonghua/Automation of Electric Power Systems,30(10),69-74.
MLA He,Wei,et al."On-line monitoring system of faulty insulator based on non-touching UV pulse method".Dianli Xitong Zidonghua/Automation of Electric Power Systems 30.10(2006):69-74.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[He,Wei]'s Articles
[Chen,Tao]'s Articles
[Liu,Xiao Ming]'s Articles
Baidu academic
Similar articles in Baidu academic
[He,Wei]'s Articles
[Chen,Tao]'s Articles
[Liu,Xiao Ming]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[He,Wei]'s Articles
[Chen,Tao]'s Articles
[Liu,Xiao Ming]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.