UM  > 科技學院  > 電機及電腦工程系
Design of LCL Filter for Harmonic Suppression in Co-phase Railway Power Quality Conditioner
Keng-Weng LAO; Man-Chung WONG; NingYi DAI; Chi-Kong WONG
2013
Conference Name1st International Future Energy Electronics Conference (IFEEC)
Source Publication1st International Future Energy Electronics Conference, IFEEC 2013
Pages794-799
Conference DateNOV 03-06, 2013
Conference PlaceTainan
CountryTaiwan,China
Author of SourceIEEE
Publication Place345 E 47TH ST, NEW YORK, NY 10017 USA
PublisherIEEE
Abstract

LCL filter has been widely used for harmonic suppression in power system converter, especially at high power conditions. For instance, in the 27.5 kV locomotive co-phase traction power, the railway power quality conditioner is a backto- back converter, and LCL filter is preferred to suppress the harmonics injected. In this paper, the design procedure of LCL filter for harmonic suppression in co-phase railway power quality conditioner is being analyzed and proposed. The influence of LCL filter parameter on its performance is being derived mathematically and discussed. Besides normal discussion of current harmonic suppression, voltage harmonic suppression performance of LCL filter is also investigated. Finally, the LCL filter design is being verified via PSCAD simulation. This paper provides a systematic design procedure for LCL parameter design, which is derived based on mathematical analysis.

DOIhttps://doi.org/10.1109/IFEEC.2013.6687610
URLView the original
Indexed BySCI
Language英语
WOS Research AreaEnergy & Fuels ; Engineering
WOS SubjectEnergy & Fuels ; Engineering, Electrical & Electronic
WOS IDWOS:000330072100142
Fulltext Access
Citation statistics
Cited Times [WOS]:3   [WOS Record]     [Related Records in WOS]
Document TypeConference paper
CollectionDEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING
AffiliationUniv Macau, Fac Sci & Technol, Taipa, Peoples R China.
First Author AffilicationUniversity of Macau
Recommended Citation
GB/T 7714
Keng-Weng LAO,Man-Chung WONG,NingYi DAI,et al. Design of LCL Filter for Harmonic Suppression in Co-phase Railway Power Quality Conditioner[C]//IEEE. 345 E 47TH ST, NEW YORK, NY 10017 USA:IEEE,2013:794-799.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Keng-Weng LAO]'s Articles
[Man-Chung WONG]'s Articles
[NingYi DAI]'s Articles
Baidu academic
Similar articles in Baidu academic
[Keng-Weng LAO]'s Articles
[Man-Chung WONG]'s Articles
[NingYi DAI]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Keng-Weng LAO]'s Articles
[Man-Chung WONG]'s Articles
[NingYi DAI]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.